首 页 新产品信息 产品报价 产品中心 技术论坛 资料下载 PLC技术培训

K7L-AT50 Liquid Leakage Sensor Amplifier
certification


K7L-AT50 Liquid Leakage Sensor Amplifier

Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity.

- Detects leakage of liquid such as isopropyl alcohol by monitoring the resistance between sensing bands
-   Detects liquids with impedance as high as 50MW
-   Four selectable sensing ranges ensure detection suited to the characteristics of the liquid
-   Incorporates a noise canceller circuit connected to a 3-conductor cable, ensuring a high level of noise immunity and reliable operation. (Patent pending)
-   Sends AC signals to the Sensing Band are isolated, allowing the installation of more than one device in the same place
-   Thin-profile, space-saving model is 13x29x46mm (W x H x D)
-   CE and UL/CSA approval

特  性
应用实例
规格型号
尺  寸

 



特性

Sensing Band boasts high degree of chemical resistance.  The K7L can be used in a wide range of applications from semiconductor production installations to food-processing equipment

Inter-electrode Resistance Detection
+ Stable detection of liquids with impedances of up to 50MWand common water.  Four sensing ranges are available ensuring detection suited to the application.  You can set it to detect, fresh water, pure water, distilled water, plating liquids, chemical liquids, and IPA (isopropyl alcohol)
Noise Canceller Function (Pat.)
+ Incorporates a noise canceller circuit that uses a 3-conductor cable, ensuring a high level of noise immunity





AC Detection Method
+ This K7L internally oscillates AC signals provided to the Sensing Band at approximately 3.75Hz, protecting the Sensing Band from electric corrosion, and ensuring safe operation


Multiple Installation
+ The power supply circuit and the detection circuit are isolated and so several Amplifiers can be installed in the same place



Sensing Band with Excellent Chemical Resistance
+ SUS316 and polyethylene are used for the Sensing Band's core and sheath respectively ensuring high resistance to both acidic and alkaline liquids


top



应用实例

Liquid Leakage Detection for Measuring Baths in CMP Devices
+ Detects liquid leaked to drain pans, and prevents damage to devices and cleaning irregularities for waters

Detection of Liquid Leakage at Pipe Joints for Chemical Liquid Tanks
+ Liquid leakage at a pipe joint can be detected by wrapping the Sensing Band around the joint


Detection of Condensation and Liquid Leakage at Semiconductor Production Installations
  Detects condensation inside cleaning devices and liquid leaked to the surroundings

Detection of Cleaning Fluid Level for Plating Devices
+ Detects the level of pure water inside plating baths.  High sensitivity allows high-accuracy control that prevents cleaning irregularities



top



规格型号
订购信息

项目 型号 原料
Liquid Leakage Sensor Amplifier K7L-AT50 ---
Sensing Band F03-16 Sheath: Polyvinyl chloride
Core: Stainless steel SUS304
F03-16PE Sheath: Polyethylene
Core: Stainless steel SUS316
Sensing Band Sticker with Adhesive F03-26 Polyvinyl chloride
F03-26PE Polyethylene
Sensing Band Sticker without Adhesive F03-26PEN Polyethylene
Terminal Block F03-20 ---
Track-mounted Socket P2RF-08-E ---
P2RF-08 ---

Note:  1.

F03-16 and F03-16PE Sending Bands are available in 1m, 2m, 5m, 10m, 15m, 20m, 25m, 50m, 75m and 100 m as standard lengths.  For example, if a 4-m-long F03-16 Sensing Band is required, place an order for F03-16 5M (5m in length).  If you need a 12-m-long F03-16 Sensing Band, place an order for F03-16 15M (15m in length).
2. The minimum order quantity of the F03-26, F03-26PE, or F03-26PEN Sensing Band Sticker is one set (containing 30 pieces).
3. The minimum order quantity of the F03-20 Terminal Block is one set (containing 10 pieces).


Ratings

Rated power supply voltage 12 to 24 VDC (Allowable voltage fluctuation range: 10 to 30 VDC)
Operate resistance 0Wto 50 MW, variable
Range 0: 0 to 250 kW
Range 1: 0 to 600 kW
Range 2: 0 to 5 MW
Range 3: 0 to 50 MW
Release resistance 105% min. of operate resistance
Output configuration NPN open collector transistor output with 100 mA at 30 VDC max.
Wiring distance Wiring cable: 50 m max
Sensing Band length: 10 m max
Accessories Terminal block (for connecting wiring cable and Sensing Band)
Screwdriver for ADJUST setting.
(Purchase the Sensing Band, Sensing Band Sticker, wiring cable, and Socket separately.)


特性

Ambient temperature Operating: -10C to 55C
Storage: -25C to 65C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Storage: 25% to 85% (with no icing or condensation)
Insulation resistance 10MWat 100 VDC between case and current-carrying parts
Dielectric strength 1,000 VDC at 50/60 Hz for 1 min between case and current-carrying parts
Power consumption 1 VA max.
Response time Operate: 800 ms max.
Release: 800 ms max.
Weight Approx. 14 g

top


尺寸
Liquid Leakage Sensor Amplifier
K7L-AT50


click to view an enlarged picture       
Track-mounted Sockets
P2RF-08-E


click to view an enlarged picture       

Liquid Leakage Sensor Amplifier
K7L-AT50


click to view an enlarged picture       

P2RF-08-E
(Round terminals can be used)
click to view an enlarged picture       

公 司 总 部: 广州市体育东路33号天盛大厦南梯707室
电   话: 020-85267788(15条线)  传真:020-85267077
东莞分公司:东莞市八达路124号电子大厦701室
网址:http://www.omrongzc.com
Email:webmaster@omrongzc.com